Current Location:Home > Products > Grout
Return to List
Xunlei 110 Colorful Universal Waterproof Coating
Main features
  • Beautiful color coating, effectively avoid leakage coating
  • Good leveling and effortless brushing
  • Good adhesion, can be firmly attached to the base surface
  • Super water resistance, alkali resistance, can adapt to long-term immersion environment
  • Can be directly constructed on the wet base surface without open water
  • Excellent matching, dry solid can be used after the appropriate tile glue paste
  • green environmental protection
Product Certification
Color
  • Blue
Product Specifications
  • 18kg per Bucket
Executive standards
  • JC/T 2090-2011 Polymer Cement Waterproofing Slurry Type I
Product overview

Thunderbolt 110 colorful universal waterproof coating is a high-quality environmentally friendly emulsion as the base material, to high quality Portland white cement, inorganic mineral material grade with aggregate by scientific ratio modulation of a two-component waterproof coating, the product has good waterproof, alkali resistance and bonding performance, widely used in indoor toilets, kitchen, balcony and other locations of the waterproof treatment

Product characteristics
Characteristic one
Low VOC, low odor, safety and environmental protection
Characteristic II
Beautiful color, avoid leakage brush
Characteristic three
Strong adhesion, tiling worry-free
Characteristic four
Smooth roll coating, efficient construction
Scope of application

bathroom, kitchen, balcony
Basement side wall
Indoor back water waterproof moisture-proof

Construction operation

【Base Layer Preparation】

Base Layer Inspection: The wall base must be solid, free of oil stains, floating dust, and other loose substances. For large holes or cracks, repair them first using mortar or leak-sealing products. For aluminum formwork concrete bases, it is recommended to treat the surface with an interface agent first.
Base Layer Moistening: Fully moisten the base with clean water. Construction can only begin when there is no visible water remaining on the base surface.

【Coating Preparation】

First, pour the liquid component into a clean empty bucket. Start stirring, then slowly add the powder component in the recommended ratio. Continue stirring while adding the powder until a uniform slurry is formed in the bucket. Mechanical stirring is mandatory to achieve optimal mixing results. After thorough stirring, let the slurry stand for maturation for approximately 3-5 minutes, then stir again for about 30 seconds before use.

【Waterproof Construction】

It is recommended to use a medium-bristle or long-bristle roller for application (a brush may be used for joint treatment). Apply the coating in thin, multiple layers as much as possible. The direction of the second coat should be perpendicular to the first. Each subsequent coat must be applied only after the previous waterproof layer has dried on the surface (typically 2-6 hours), until the required thickness is achieved.
Apply two or more coats of the waterproof layer. The total thickness of the waterproof layer must be at least 1.5mm, and the thickness of each individual coat must not exceed 1mm to facilitate proper curing.
After construction is completed, conduct a comprehensive inspection of the entire surface. Promptly address any areas where the coating was missed.
Once the coating film is completely dry, a water-tightness test can be performed.

【Recommended Dosage】

When the coating film thickness is 1.0mm, the theoretical dosage is approximately 2.1±0.2kg/m² (the actual dosage may vary depending on the flatness of the base layer).

Precautions

should be at a temperature of 5 ℃ ~ 35 ℃, air relative humidity ≤ 85% under the conditions of construction; low temperature or high humidity environment, can be appropriate to extend the subsequent construction time, high temperature climate should pay attention to ensure that the base is wet enough
Before the product is used, the mixing equipment should be prepared, and manual mixing is strictly prohibited.
The stirred slurry should be used up within 1 hour, and the solidified material should not be reused
with water. Waterproof construction should adhere to the principle of first node treatment and then large surface, should first deal with the root, yin and yang angle position of the node
It is recommended to support our brand tile glue for paving construction
In the basement and air circulation places, please try to avoid high humidity and air temperature for construction, fan auxiliary ventilation
can be used

Transportation and storage
  • Storage conditions
    The product should be stored in a cool and ventilated place, no exposure, rain
  • Transportation requirements
    During transportation, prevent rain, sun exposure, cold, squeeze and collision, and keep the package intact.
  • Warranty Period
    From the date of production, the shelf life of the product is 12 months at a storage temperature of 5-35°C.
FAQ
Q
The coating may stratify, precipitate or form a skin on the surface after storage
A
The storage temperature is too high, the seal is not tight, or it has been left for a long time without stirring.
Solution Store as required by the instruction manual (such as away from light and in an environment of 5 to 35℃);
Q
The coating does not cure for a long time after application
A
1. Incorrect two-component ratio;
2. Low-temperature or high-humidity environment;
Solution: Mix strictly in proportion and use an electric mixer.
2. The ambient temperature should be between 5 and 35 degrees Celsius, and ventilation should be enhanced.
Q
Cracks appear in the coating or it detaches from the base layer
A
The base layer has not been cleaned (with loose dust and oil stains).
2. Applying too thick a single coat;
3. The material is incompatible with the base layer.
Solution: 1. Clean the base layer and moisten it (without standing water);
2. Apply thin coats multiple times (0.5 to 1mm per layer);
3. The corners are rounded and the reinforcing material 249 is added.
Q
There are fine holes or bulges on the surface of the coating
A
1. The base layer contains pores, and gas escapes during painting.
2. Exposure to high temperatures or excessive application.
Solution: 1. Moisten the base layer to saturation before construction;
2. Adopt a thin-coating process and avoid construction under direct sunlight.
3. Remove the bulging part and then repair it.
Q
The coating sags on the vertical surface, resulting in uneven thickness
A
Applying too thickly at one time or using improper construction methods.
Solution: Apply in three coats up to 1.5mm, crossing the horizontal and vertical directions.
2. Use a toothed scraper to control the thickness.
Q
Leakage occurs during the water-tightness test or after use
A
1. The coating has missed areas and pinholes.
2. The cracks in the base layer have not been treated or the quality of the materials is poor.
Solution: Repair the defective areas, reapply the paint and conduct a water-tightness test.
2. Additional layers should be added to important parts (such as the root of the pipe).
Q
The surface of the coating is white, discolored or uneven in color
A
1. Construction in damp environments (whitening);
2. Ultraviolet radiation or chemical erosion (discoloration).
3. Improper proportioning of two-component products (uneven color) Solution: 1. Select anti-whitening coatings and ensure the base layer is dry;
2. Weather-resistant coatings should be selected for outdoor use (coatings that can be used exposed).
Q
Paints release harmful gases (such as VOCs)
A
Using inferior or non-environmentally friendly materials.
Solution: 1. Choose low-VOC and non-toxic products (such as polymer cement-based coatings);
2. Ensure good ventilation during construction and wait until it has cured before moving in.
Preventive measures: 1. Base treatment: Ensure it is solid, flat, and free of oil stains. Base surfaces with high water absorption rates need to be moistened.
2. Material Selection: For damp substrates, choose coatings with strong adhesion (such as cement-based permeable crystalline type).
High-elasticity coatings (such as polyurethane) should be used for high-deformation areas.
3. Environmental Control: Avoid construction on rainy days, in winds of force 5 or above, or in extreme temperatures.
4. Process Specifications: The total thickness of the coating is ≥1.2mm (for organic coatings) or ≥3.0mm (for cement-based coatings).
The joint width should be no less than 100mm to avoid any missed coating.
Special Scene Precautions:
1. Basement project: Reactive coatings are recommended for the water-facing side, while cement-based coatings are suitable for the water-facing side.
2. Winter construction: Prefer reactive coatings to avoid the problem of low-temperature curing.
3. Renovation of old layers: Thoroughly remove the original coating and, if necessary, use an interface agent to enhance adhesion.
By standardizing material selection, strict construction and post-construction maintenance, the occurrence of problems with waterproof coatings can be significantly reduced. If the problem has already occurred, it should be repaired in a targeted manner based on the specific cause, and priority should be given to checking the compatibility of the grassroots level and materials.

WeChat

WeChat Channels

TikTok